0
0
Shop By Vehicle
Top Categories
All Categories

Top Categories

All Categories


Hi, ! (Not you?)
My Account
1-800-345-4545
Track Order
Help
Altronics PA2-02-PG

Altronics PerformAIRE Portable

030-PA2-02-PG

made in usa
Free Shipping

$1,945.99
Altronics PerformAIRE Portable $1,945.99
Out of stock
To order this item contact Customer Service at 1-800-345-4545.
PerformAIRE
  • Portable
  • Ultra Quick Response
  • 1 Run Predictions
  • With Oxygen Sensor
  • With Paging
  • Altronics PA2-02-PG Details

    Weather Stations

    Specifications:

    Manufacturer's Part Number:
    PA2-02-PG

    Racing's Most Precise Weather Station with ET Prediction

    Minimize the guesswork regarding a vehicle's race performance with a portable PerformAIRE, the only patented weather station. PerformAIRE's V6.0 air-quality computer monitors temperature, relative humidity, barometric pressure, and the amount of oxygen in the atmosphere through state-of-the-art sensors*. Then the information is sent to a microprocessor where density altitude, oxygen altitude, and projected values are calculated using equations formulated specifically for internal combustion engines.

    The PerformAIRE computer has an expandable database to store vehicle runs and use the results to predict elapsed times, throttle stop settings, jet sizes, etc. Projected values are continually updated with each new air sample (density altitude and oxygen altitude are saved with each run when an O2 sensor has been installed). Stored runs are date/time stamped for later reference, and hundreds of runs can be labeled individually for particular vehicles or tracks. Database details can be downloaded to a personal computer as a spreadsheet that automatically charts vehicle performance vs. the changing atmosphere. This allows bad runs to be deleted from the database to deliver more accurate predictions.

    PerformAIRE is superior to other weather stations/calculators because of its ability to accurately and repeatedly measure current race conditions. Detecting minor atmospheric fluctuations can be the difference between losing and winning. On average, a 1° change in temperature, 0.1 in/Hg change in pressure, 10% change in humidity, or 0.1% change in oxygen can equal more than a 100' change in altitude. Variations in temperature, pressure, humidity, and oxygen level do not equate linearly with altitude, so consistently wrong readings should not be considered dependable for generating correct outcomes (e.g. a gauge that always displays 5° higher than the actual temperature cannot provide a valid prediction).The PerformAIRE air quality computer's state of the art sensors allow it to measure density altitude with an accuracy of better than plus or minus 50 feet over the entire temperature range and with even closer repeatability. No other weather station, digital or mechanical, can claim this degree of accuracy. Not even other all in one digital weather station has this degree of accuracy!

    Features
  • Large LCD
  • Easy-to-Read Keypad
  • Capable of Storing 400 Runs
  • 10 Databases (Can be upgraded to download & analyze data)
  • ET, Throttle Stop, Single Run, and Multiple Variable Predictions
  • Dew Point
  • Temperature
  • Sea Level ET
  • Density Altitude
  • Vapor Pressure
  • Relative Humidity
  • Last Air Sample Hold
  • Absolute Barometric Pressure
  • Throttle Stop & Air Density Ratios
  • Run Completion and Bad Run Detection
  • Wind Correction (Can be adjusted for multiple vehicle body types)

    *Optional O2 sensor measures percentage of oxygen in atmosphere to help determine how engine output might be affected

  • Some parts are not legal for use in California or other states with similar laws / regulations

    Motor Vehicles

    WARNING: Motor vehicles contain fuel, oils and fluids, battery posts, terminals and related accessories which contain lead and lead compounds and other chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. These chemicals are found in vehicles, vehicle parts and accessories, both new and as replacements. When being serviced, these vehicles generate used oil, waste fluids, grease, fumes and particulates, all known to the State of California to cause cancer, birth defects, and reproductive harm.

    Tools:

    WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Some examples of these chemicals are: lead from lead-based paints, crystalline silica from bricks and cement and other masonry products, and arsenic and chromium from chemically treated lumber. Your risk from exposure to these chemicals varies, depending on how often you do this type of work. To reduce your exposure, work in a well-ventilated area and with approved safety equipment, such as dust masks that are specially designed to filter out microscopic particles.

    Electrical Cords

    WARNING: The wires of these products contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.