Digital Thermatic Fan Switch
This exclusively designed Digital Thermatic Fan Switch Kit can be used with Thermatic Electric Fans, EWP's and competitors Fans. It senses air temperature as it passes through the radiator with the sensor placed in the radiator fin section or the sensor can now also be placed directly into the coolant system in combination with a Temperature Sensor Adaptor Kit (Part # 317-DC-0409). It can be used for 12 or 24* volt applications and has an adjustable temperature range of 104ºF to 230ºF (40°C to 110°C) which can show Centigrade or Fahrenheit. Temp is set by pressing the set button. It can run 1 or 2 fans. The second fan (if applicable) will start 10 seconds after Fan #1 runs. It operated thermally & also when the air conditioning is in operation.
Specifications:
- Max voltage: 12 to 27V (For 24V, relays need to be changed, not supplied in kit)
- Max current: 40A per Fan
- Relay setup: Dual relay
- Speed: Single speed, 10 second delay to start up the second fan
- Applications: Suitable for single and dual fan applications
- Screen Display: LED digital temp display, actual temp + set temp
- Temp Display: Centigrade or Fahrenheit
- Temp settings: 40°c to 110°c (104°F to 230°F)
- Temp setting: Push Button
- Circuit type: Pre-programmed micro controller
- Output wires: Batt + Batt - IGN, AC Clutch, Fan #1, Fan #2 Thermistor Probe
- Dimensions: 3-3/4" (95mm) x 2-9/16" (65mm) x 2-3/16" (56mm)
- The unit is NOT WaterProof
*Note: if using this switch for use with our EWP's, it will not vary the speed of the pump in response to engine temperature but rather turn the pump on and off at your set temperature. For EWP control, we would recommend part number 8001 which can manage both the EWP and your Thermatic Fans.
*Note: Kit sold in 12 volt configuration, for 24 volt application, you will need to change the two relays with 2 x 24 volt units which are not supplied in the kit.
Specs | Part #0444 | Part #0455 |
Maximum voltage | 10V to 16V | 10V to 16V |
Maximum Current | 50A – Each Fan | 50A – Each Fan |
Relay setup | Dual Relay | Dual Relay |
Speed | Single Speed, 10-Second Delay to Start Up the Second Fan | Single Speed, 10-Second Delay to Start Up the Second Fan |
Applications | Recommended for All DCPL Fans incl. (2) 14"HP or (2) 16" Fans | Recommended for All DCPL Fans incl. (2) 14"HP or (2) 16" Fans |
Temperature Display | LED Digital Temp Display – Actual Temp + Set Temp | LED Digital Temp Display – Actual Temp + Set Temp |
°C + °F Setting | LED Display °C or °F | LED Display °C or °F |
°C to °F change | Press & Hold Set Button 5 Seconds | Separate °C to °F Change Button |
Temperature settings | 40°C to 110°C 104°F to 230°F | 40°C to 110°C 104°F to 230°F |
Temperature setting method | Push Button | Push Button |
Temperature reduction range | -5°C from Set / Target | -5°C from Set / Target |
Temperature detection | Air or Coolant (For Coolant Temp, Must Use Part #0409 Sensor Adaptor Kit– Not Supplied) | Air or Coolant (For Coolant Temp, Must Use Part #0409 Sensor Adaptor Kit – Not Supplied) |
Accuracy | 99.9% | 99.9% |
Circuit type | Pre-Programmed Micro Controller | Pre-Programmed Micro Controller |
Output wires | Battery + Battery - IGN, A/C Clutch Fan #1, Fan #2 Thermal Probe | Battery + Battery - IGN, A/C Clutch Fan #1, Fan #2 Thermal Probe |
Unit mount location | Engine Bay | Driver’s Compartment / Dashboard |
Probe lead length | 35.4" | 118.1" |
Fan operation indicator | N/A | Twin Fan Operation Will Illuminate via Fan #1, Fan #2 LEDS |
A/C Override indicator | N/A | Indicated via Air Con LED |
Temp set mode indicator | N/A | Indicated via Temp Set Mode LED |
Design | Relays & Wiring Built Into the Unit | Separate Wiring Looms Provided / Plug & Play Unit Relays Built Into the Wiring Loom |
Faults Display | N/A | Temp Sensor – |
Dimensions | 3.74" x 2.56" x 2.20" | 3.15" x 2.75" x 1.06 |
Specifications:
Will this work with dual speed fan?
will this kit work with the courgar xr7 fan?
Where does the fan clutch wire go to if I do not have an ac system?
Motor Vehicles
WARNING: Motor vehicles contain fuel, oils and fluids, battery posts, terminals and related accessories which contain lead and lead compounds and other chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. These chemicals are found in vehicles, vehicle parts and accessories, both new and as replacements. When being serviced, these vehicles generate used oil, waste fluids, grease, fumes and particulates, all known to the State of California to cause cancer, birth defects, and reproductive harm.
Tools:
WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Some examples of these chemicals are: lead from lead-based paints, crystalline silica from bricks and cement and other masonry products, and arsenic and chromium from chemically treated lumber. Your risk from exposure to these chemicals varies, depending on how often you do this type of work. To reduce your exposure, work in a well-ventilated area and with approved safety equipment, such as dust masks that are specially designed to filter out microscopic particles.
Electrical Cords
WARNING: The wires of these products contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.